UPS在線式交流不間斷電源

點(diǎn)擊查看原圖
公司名稱:北京市北方思源電子技術(shù)中心
所屬類別:電源產(chǎn)品分類>>UPS電源
電子信箱:52634729@qq.com
聯(lián)系電話:010-62123259
聯(lián) 系 人:北方思源
更新時(shí)間:2012/2/10 14:33:09
 
產(chǎn)品詳情

SANTAK CASTLE 6KVA
在線式交流不間斷電源

EXTERNAL BATTERY(外接電池):274V/25A
INPUT(輸入交流電壓):176-276V~ 50Hz 29.6A MAX
OUTPUT(輸出交流電壓):220V~ 50Hz 27.3A MAX
6KVA COS∮=0.7
INPUT BREAKER:30A/250V
OUTPUT BREAKER:30A/250V

Protection is a must for numerous types of equipment in the computer room. No matter whether it is the main computer unit, workstation, network server or any other high precision equipment normal operation. Santak CASTLE Series 6K, 10K UPS are specially designed to meet the computer room. On-line intelligent UPS is capable of simplifying the power supply work in the computer room and upgrading the operating reliability of computer systems.

Santak CASTLE Series 6K, 10K UPS make use of the unique AC-DC conversion circuitry to detect the electricity current and voltage output of utility power supply. The current is input via the high frequency PWM to maintain uniform wave form and phase in line with the voltage, so as to attain high input power factor over 95% and avoid generating comparatively significant harmonic interference on the power network. It can be placed in the computer room next to other computer equipment. The on-line sine wave design of Santak CASTLE Series 6K, 10K UPS are suitable for all high precision equipment in the computer room. With normal utility power supplied via the AC-DC circuit, the DC bus voltage is obtained and then the inverter converts the DC bus into 220V AC output. Therefore, the power used by the load is a purified sine wave power of regulated voltage and regulated frequency with noisy signals filtered. With the use of the outstanding IGBT as the power conversion component, the operating frequency of the inverter of UPS is capable of reaching tens of KHz, due to the high frequency operating characteristics of IGBT. Higher working efficiency of the inverter also improves the overall efficiency of UPS. Moreover, higher inversion frequency reduces the noise of the inverter as well. As a result, the placement of 'CASTLE' Series UPS right in the computer room will not affect your work.

Application
Power Manager in the computer room

Key Features
Microprocessor control
By means of innovative software control programs, the complicated hardware circuitry is inlaid in the powerful Motorola microprocessor. Apart from reduced size, it also lowers the defective rate of UPS.
High quality battery
The selection of Panasonic Sealed Lead-Acid maintenance free battery maximizes the life span of the battery for enhanced economic benefits.
RS232 communication port
Connection of Santak Power Management software for power detection and monitoring via RS232 digital communication port enables direct on-screen monitoring of the status of power supply and UPS, so as to simplify the network management work and improve the reliability of computer system.
Centralized control front panel
The easy-to-read display of the centralized control lets you know at one glance the operation and the load status of UPS as well as the power supply status of the battery etc. In other words, you will be able to monitor the power supply quality of UPS and any change of the application environment at any time.
Easy control
The elegantly designed soft-touch button makes operations easily. Simply press the button softly and the power will be turned on.
Automatic detection
When the UPS is powered on, it immediately performs an inspection of the components such as the inverter and the battery as well as the load, so as to detect any problem in time to avoid causing any negligence or loss.
Self-protection
Equipped with the comprehensive self-protection design, no matter whether UPS is overloaded or short circuited, or the battery voltage is excessively low, or the temperature of UPS is too high, the UPS will be switched off automatically.
Remote monitoring
The UPS is equipped with an Intelligent Slot (SNMP slot) to allow communication among various operation systems and remote monitoring of the UPS.
Alarm silence
The real-time alarm silencing function eliminates the unnecessary and annoying noises.
DC Power-on/Power-off
The unique DC power-on function elaborates the emergency standby capability of UPS to a sufficient extent.

Specification

Product

 

Castle

Model

 

C6K

Rated Power

Volt-Amps/Watts (VA/W)

6KVA/4.2KW

Input

Nominal Voltage

220Vac

Voltage Window

176 ~ 276Vac

Frequency Range

46.5Hz ~ 55Hz

Phase

Single phase with ground

Current (A)

24A (30A max.)

Power Factor

0.97

Output

Voltage

220Vac +/-3%

Frequency

50Hz +/-0.5% (Battery mode)

Wave-form

Sine wave

Power factor

0.7

Distortion

< 5%

Overload Capability

105~130% for 10 min., 130% for 1 sec. (Line mode)
105% for 1 sec. (Battery mode)

Current Crest Ratio

3:1 max.

Battery

Type

Sealed Lead-Acid, Maintenance free (Panasonic)

Capacity

Twenty 12V7.0Ah

Back-up time (Full load)

8 min

Recharge time

8 hrs to 90% of full capacity after full load discharge

Transfer time

 

0

LED indicators

Status

Load level/Battery level, Battery, Utility power, Inverter, Bypass, Overload, Fault

Audible alarm

Battery mode

Alarm beeps every four seconds, every second if battery discharge near ending

Overload

Alarm beeps two for every second

Fault

Alarm beeps continuously

Acoustic noise

At 1 meter distance

< 55 dBA

Communications

DB-9 Port

RS-232 Serial Interface; Power monitoring and unattended System(s) shutdown via WinPower software

Intelligent Slot (SNMP)

Power Management from SNMP manager and Web browser via WebPower (Option)

Input/Output Connection

 
Terminal Block

Environment

Operating temperature

0 ~ 40 deg.C;

Operating humidity

20% ~ 90% non-condensing

Weight

Unit

89 Kg

Shipping

92 Kg

Dimensions
(W x D x H
)

Unit

260 x 555 x 710 mm

Shipping

465 x 842 x 990 mm

關(guān)于該條產(chǎn)品信息,我有如下留言:
請(qǐng)您注意:
·遵守中華人民共和國(guó)的各項(xiàng)有關(guān)法律法規(guī)
·承擔(dān)一切因您的行為而導(dǎo)致的法律責(zé)任
·本網(wǎng)留言板管理人員有權(quán)刪除其管轄的留言內(nèi)容
·您在本網(wǎng)的留言內(nèi)容,本網(wǎng)有權(quán)在網(wǎng)站內(nèi)轉(zhuǎn)載或引用
·參與本留言即表明您已經(jīng)閱讀并接受上述條款
用戶名: 密碼: 匿名留言   免費(fèi)注冊(cè)電源在線網(wǎng)會(huì)員,獲取更多服務(wù)!立刻注冊(cè)
免責(zé)聲明:以上所展示的信息由會(huì)員自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布會(huì)員負(fù)責(zé)。電源在線對(duì)此不承擔(dān)任何保證責(zé)任。
企業(yè)商柜
關(guān)閉